SUBTOTAL:
$0.00
Unit Size | Pricing |
Each(1): | $1132.95 |
Select Location | |
Ajax: | Extended Delivery |
Burnaby: | Extended Delivery |
Calgary: | Extended Delivery |
Dartmouth: | Extended Delivery |
Edmonton: | Extended Delivery |
Fort McMurray: | Extended Delivery |
Grande Prairie: | Extended Delivery |
Kelowna: | Extended Delivery |
Kitimat: | Extended Delivery |
London: | Extended Delivery |
Mississauga: | Extended Delivery |
Ottawa: | Extended Delivery |
Paradise: | Extended Delivery |
Pointe-Claire: | Extended Delivery |
Québec: | Extended Delivery |
Saint John: | Extended Delivery |
Saskatoon: | Extended Delivery |
Sudbury: | Extended Delivery |
Timmins: | Extended Delivery |
Victoria: | Extended Delivery |
Winnipeg: | Extended Delivery |
No locations available for selected province. |
The PRC30 is a Multifunction Process Calibrator. This calibrator provides precision sourcing and measurements for thermocouples (eight types), current (mA), and voltage (mV and V) devices. Featuring 24 volt loop power, five user adjustable calibration presets, and temperature output in Fahrenheit, Celsius, and millivolts.
Attributes | |
---|---|
Display Type | LCD |
Thermocouple Type | J, K, T, E, C, R, S and N |
Thermocouple Temperature Measuring Range | -58 to 1832 deg F (-50 to 1000 deg C) Type J, -58 to 2498 deg F (-50 to 1370 deg C) Type K, -184 to 752 deg F (-120 to 400 deg C) Type T, -58 to 1382 deg F (-50 to 750 deg C) Type E, 32 to 3182 deg F (0 to 1750 deg C) Type C, R, S, -58 to 2372 deg F (-50 to 1300 deg C) Type N |
Thermocouple Temperature Accuracy | +/-(0.05% + 2 deg F or 1 deg C) Type J, +/-(0.05% + 2 deg F or 1 deg C) Type K, +/-(0.05% + 2 deg F or 1 deg C) Type T, +/-(0.05% + 2 deg F or 1 deg C) Type E, +/-(0.05% + 2 deg F or 1 deg C) Type C, R, S, +/-(0.05% + 2 deg F or 1 deg C) Type N DC Source; +/-(0.05% + 1.8 deg F or 1 deg C) Type J, +/-(0.05% + 1.8 deg F or 1 deg C) Type K, +/-(0.05% + 1.8 deg F or 1 deg C) Type T, +/-(0.05% + 1.8 deg F or 1 deg C) Type E, +/-(0.05% + 2 deg F or 1 deg C) Type C, R, S, +/-(0.05% + 2 deg F or 1 deg C) Type N DC Measurement |
Voltage Measuring Range | 0 to 1999 mVDC, 2 to 20 VDC |
Voltage Accuracy | +/-0.01% |
Current Measuring Range | 0 to 50 mA DC |
Current Accuracy | +/-0.01% |
Source Current | 0 to 24 mA DC |
Source Current Accuracy | +/-0.01% |
Source Voltage | 0 to 2000 mVDC, 0 to 20 VDC |
Source Voltage Accuracy | +/-0.01% |
Loop Supply Voltage | 24 V |
Maximum Load | 1000 ohm at 24 mA DC Source |
Power Supply | 100 to 240 VAC |