Drager X-am 2500 Personal Gas Detector

Drager X-am 2500 Personal Gas Detector

The Drager X-am 2500 Personal Gas Detector accurately detects O2, CO, NO2, SO2 and H2S for a wide range of applications. It combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety. The X-am 2500 has a large, easy to read, liquid-crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2. This device can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours. The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. This gas detector has Ex approval for Zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.

The Drager X-am 2500 is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front, even if the instrument is inside a pocket or if the front gas entry is accidentally covered. The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations. The X-am 2500 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the O2 sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.

An optional external pump with a hose up to 98 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

The X-am 2500 is compatible with both the Drager X-dock Calibration Station and the Drager Bump Test Station.


Upcoming Events
23 Oct 2017

Ladder Safety Training

Calgary, AB
23 Oct 2017

WHMIS (Workplace Hazardous Materials Information System) 2015

Burnaby, BC
23 Oct 2017

Fall Protection End User

Burnaby, BC
image description Watch our 3 minute video